Suggestions on extending the service life of beam light sources

Wednesday, 04/23/2025
Discover expert tips from Vanray on extending the service life of your beam light, including maintenance advice for beam moving head and 295 beam moving head fixtures. Improve performance and reliability with our professional guidance.
led par light for theater

 

(1)     Suggestions for the use of switch bulbs

1.Try not to extinguish the bulb within 5 minutes after it is lit. At this point, the bulb has not yet reached thermal equilibrium and is prone to blackening, eventually causing the bulb to lose its transparency and shortening its service life.

 

2.After the bubbling command is given, it may be subject to external high-frequency interference, and some lamps may receive the bubbling signal later or receive incorrect signals. It is recommended that if the lamp still does not light up after 2 minutes of lighting, reset the entire lamp and then light it again.

 

3.For users with the necessary conditions, when turning off the bulbs, it can be set uniformly to the horizontal state of the lamp head (Y-axis) to extinguish the bulbs (in this state, the heat dissipation of the light source on both sides is the most balanced), which is quite helpful in reducing the cold cracking or bubble explosion of the bulbs. If it is in an inclined state, the heat will be biased towards one side of the wick, which is more likely to cause thermal imbalance.

 

4.Try to avoid frequently turning on and off the bulbs of lamps, especially within one minute after turning on the bulb. If the bulb is turned off within one minute, it is very likely that the mercury inside the bulb will cool into large particles. Especially for new bulbs, it is more likely that the mercury droplets will short-circuit the bulb electrodes, which will result in the bulb not being lit. At this point, you need to remove the bulb, gently tap it with your hand to throw the mercury onto the inner wall of the bulb, and the short circuit will be relieved. Then you can light it again.

 

(2) Suggestions for using in standby mode

1. Do not keep the lamp in a static state for a long time (when the bulb is on). Try to slowly rotate the XY axis of the lamp at a large Angle to make the heat dissipation of the lamp bulb more balanced.

 

2. For users whose usage scenarios are those where the lamp head remains at a fixed Angle for a long time, it is advisable to alternate their use by adjusting the XY axis rotation as much as possible while the direction of the lamp head remains unchanged.

 

3. If alternating use is not possible, the lamp head can be slowly shaken 10 minutes before the bubble is extinguished after the activity ends (both the XY axes move from 0 to 255 simultaneously) to release the stress generated at a fixed Angle and slow down the accumulation of stress.

 

4. After the bubbles on the control console are extinguished, the lamps should be powered off in time to reduce the rate of cold cracking and bubble explosion.

 

(3) Other suggestions

When a lamp is not powered on and does not light up for a long time, the light source will still age over time, resulting in a shortened lifespan of the light source. It is recommended that the lamps be powered on regularly and operate with bright bulbs.

Tags
Waterproof gobo projector
Waterproof gobo projector
customized theater led fresnel spotlight
customized theater led fresnel spotlight
led studio light
led studio light
water wave light projector
water wave light projector
230w beam moving head light
230w beam moving head light
professional led par light
professional led par light
Recommended for you

Top Tips for Using Outdoor LED Gobo Projectors in Events and Venues

Top Tips for Using Outdoor LED Gobo Projectors in Events and Venues

How to Choose the Right Stage Lighting Manufacturer: Insights on Moving Head and LED PAR Lights

How to Choose the Right Stage Lighting Manufacturer: Insights on Moving Head and LED PAR Lights

Led 1200w profile moving head powerful led module frame

Led 1200w profile moving head powerful led module frame

VANRAY beam spot wash 380 moving head 3 in 1 moving head

VANRAY beam spot wash 380 moving head 3 in 1 moving head

IP65 19x40w rgbw bee eye led moving head

IP65 19x40w rgbw bee eye led moving head
Prdoucts Categories
FAQ
About Product
Can you accept the sample order?

Yes, we can. The sample order for trial is acceptable.

About Company
Can I Visit your company?

Of course, our company is located in No. 7, Sijiaowei Industrial Zone, Tanbu Town, Huadu District, Guangzhou, China. Warmly welcome to visit our factory.

About Logistics
Does your product support global logistics and distribution?

Yes, our products support global logistics and distribution services, and you can receive our products anytime and anywhere.

How long does logistics delivery take?

Shipping times depend on your location and the shipping method you choose

1. 5-7 days by express

2. 20–25 days by sea shipping.

3. 15 days by air shipping.

About Customized Services
Can you provide OEM / ODM services ?

Yes, we can support OEM/ODM services for the details, which can be negotiated with our sales team.

You may also like

VANRAY LED Beam Moving Head Light VR-400B 400W Beam Moving Head LED

VANRAY LED Beam Moving Head Light VR-400B 400W Beam Moving Head LED

VANRAY Waterproof LED Par Light LP-200Z 200W Zoom Par Light

VANRAY Waterproof LED Par Light LP-200Z 200W Zoom Par Light

VANRAY LED Par Zoom Wash LP-1515Z 15pcs 15W RGBW Waterproof LED Par Light

VANRAY LED Par Zoom Wash LP-1515Z 15pcs 15W RGBW Waterproof LED Par Light

VANRAY Theater LED Par Can Lights LP-350SJL 350W White LED Par Can Lights

VANRAY Theater LED Par Can Lights LP-350SJL 350W White LED Par Can Lights

Get in Touch With VANRAY

Create unforgettable stage moments with our advanced lighting solutions!

Contact us now by filling out the form below or calling us directly to begin your lighting journey!

Please enter your name not exceed 100 characters
The email format is not correct or exceed 100 characters, Please reenter!
Please enter a valid phone number!
Please enter your field_655 not exceed 150 characters
Please enter your content not exceed 3000 characters
Contact customer service

Contact VANRAY

Hi,

If you are interested in our products, customized or have any doubts, please be sure to let us know so that we can help you better.

×
Please enter your name not exceed 100 characters
The email format is not correct or exceed 100 characters, Please reenter!
Please enter a valid phone number!
Please enter your field_655 not exceed 150 characters
Please enter your content not exceed 3000 characters

Get a free quote

Hi,

If you are interested in our products, customized or have any doubts, please be sure to let us know so that we can help you better.

×
Please enter your name not exceed 100 characters
The email format is not correct or exceed 100 characters, Please reenter!
Please enter a valid phone number!
Please enter your field_655 not exceed 150 characters
Please enter your content not exceed 3000 characters

Send my request

Hi,

If you are interested in our products, customized or have any doubts, please be sure to let us know so that we can help you better.

×
Please enter your name not exceed 100 characters
The email format is not correct or exceed 100 characters, Please reenter!
Please enter a valid phone number!
Please enter your field_655 not exceed 150 characters
Please enter your content not exceed 3000 characters

Get your FREE ticket

Get your FREE ticket to explore the latest innovations and connect with industry leaders! Limited slots available — contact us now to secure yours!

×
Please enter your name not exceed 100 characters
The email format is not correct or exceed 100 characters, Please reenter!
Please enter a valid phone number!
Please enter your field_655 not exceed 150 characters
Please enter your content not exceed 3000 characters

Upcoming Exhibitions

Integrated Systems Europe (ISE) in Barcelona

Booth: 8M250

Date: 3-6 February 2026